Georg Fischer · GF Piping Systems
Valves and fittings, in use
Thermoplastic valves and fittings from GF's catalogue, each drawn installed where you would usually find it and set moving the way it works on site. Readouts and tables come from GF's 2026 technical datasheets. Hover, click or use the arrow keys and Space on each figure.
Ball valve Type 546 Pro
Isolation in a PVC-U process or dosing line, with true union ends
- Kv now
- –
- Flow
- –
- Flow, m³/h
- –
- Velocity in d63
- –
| Size shown | d63 / DN50, PVC-U, solvent-cement sockets (range d16–d110, DN10–DN100) |
|---|---|
| Pressure rating | PN16 for PVC-U, PVC-C and PVDF at 20 °C; ABS and PP-H PN10 |
| Temperature, PVC-U | 0 to 60 °C; full PN16 to 25 °C, derated above |
| Kv100 (fully open) | 3,100 l/min at DN50 · 700 at DN25 · 11,000 at DN100 |
| Flow characteristic | Kv ≈ 10 % of Kv100 at 40 % opening, 50 % at 80 %, 78 % at 90 % (GF chart) |
| Flow model in the figure | Q = Kv · √Δp for water at 20 °C; velocity in d63 × 4.7 PVC-U PN16 pipe (bore 53.6 mm, ISO 1452-2) |
| Dimensions, d63 | L 183 mm · union nut Ø 124 mm · axis to lever top 116.5 mm · axis to base 64 mm · lever 152 mm |
| Operating torque | ≈ 10 Nm at DN50 (GF chart); size actuators at about 2× |
| Materials | Body to suit the line (PVC-U shown) · lever PP-GF30 · seats PTFE · O-rings EPDM or FKM · stainless threaded inserts |
| Lever | Faceted wing lever (Red Dot 2020) on a locking ring: press the ring down to set and padlock the position; the lever carries the union-bush tool |
| Features | True union ends · double stem seals · M8 mounting inserts 45 mm apart · ISO 5211 top flange · EN ISO 16135 |
Sources: GF 546 Pro datasheet
Butterfly valve Type 567
Isolation and throttling in a PVC-U cooling-water main, wafer pattern between flanges
| Size shown | DN100 / d110 in PVC-U, PP-GF30 outer housing (range DN50–DN600; PVC-U, PVC-C and ABS to DN300) |
|---|---|
| Pressure rating | PN10 for DN50–DN300 with a manual lever; PN6 DN350–400, PN5 DN450, PN4 from DN500 |
| Kv100 (fully open) | 3,800 l/min at DN100 · 740 at DN50 · 50,000 at DN300 |
| Dimensions, DN100 | Face to face 56 mm · body Ø 161 mm · Hmax 342.2 mm · lever 255.5 mm · disc protrusion Q1 88 mm |
| Operating torque | 38 Nm at DN100 (12 at DN50, 145 at DN300); can rise up to 4× in service |
| Lever | Lockable lever with index plate in 5° steps; fine-adjustment lever option in 1° steps |
| Materials | Inner housing and disc PVC-U, PVC-C, ABS, PP-H or PVDF · seals EPDM, FKM or PTFE/FKM · stainless shaft |
| Design | Double-eccentric disc · EN ISO 16136 · install length EN 558 series 25 (DN50–200) · ISO 5211 for electric, pneumatic or gear actuators |
Sources: GF 567/578 datasheet · GF US Type 567 sheet (distributor-hosted)
Diaphragm valve Type 514
Throttling and shut-off in a PVC-U chemical-dosing or ultrapure-water line
| Size shown | d32 / DN25, PVC-U, union ends with solvent-cement sockets (514 range d16–d63, DN10–DN50) |
|---|---|
| Pressure rating | PN10 with the PP-GF30 housing nut; PN16 (water only, PVC-U and PVDF) with the PPS-GF40 nut |
| Temperature, PVC-U | 0 to 60 °C |
| Kv100 (fully open) | 481 l/min at DN25 · 125 at DN15 · 1,728 at DN50; linear characteristic |
| Dimensions, DN25 | Lmax 166 mm · z 124 mm · union Ø 58 mm · axis to top 107 mm · handwheel Ø 87 mm · axis to base 22 mm |
| Max. torque, DN25 | 8 Nm (PN10) / 9 Nm (PN16), GF chart |
| Diaphragms | EPDM (black), PTFE/EPDM (white), FKM (red), NBR (blue); gaskets EPDM or FKM |
| Features | Lockable handwheel · two-colour position indicator · no exposed metal screws · ENSAT mounting bushings · dead-space free and drainable · EN ISO 16138 |
Sources: GF 514–519 diaphragm valve datasheet
ELGEF Plus electrofusion coupler
Jointing PE100 water and gas mains in the trench, with a fusion control unit
| Size shown | d110 SDR11 PE100 (SDR11 range d20–d315; d20–d63 with integral pipe fixation) |
|---|---|
| Pressure rating, SDR11 | Water 16 bar · gas 10 bar |
| Dimensions, d110 | Outside Ø 138 mm · length 145 mm · insertion depth 72 mm per side |
| Connection | 4 mm terminal pins · limited-path fusion indicators · removable centre stop (to d160) |
| Fusion data shown | 40 V · 200 s: ELGEF Plus PE100 RT, d110. GF doesn't publish these for the standard coupler; the fusion unit reads them from the barcode |
| Cooling, d75–d110 | Clamps off after 10 min · pressure test ≤ 6 bar after 20 min · ≤ 18 bar after 60 min |
| Preparation | Scrape the oxidised skin over the insertion depth, mark it, insert both ends to the centre stop, and clamp |
Sources: ELGEF Plus d20–d63 datasheet · ELGEF Plus d75–d315 datasheet · ELGEF Plus PE100 RT datasheet (fusion data) · GF UK PE catalogue (cooling times, older edition)
Illustrations are explanatory drawings built from published dimensions and data, not GF artwork. Check the current GF data sheet and planning guidelines before specifying or installing. Pressure ratings are for water at 20 °C unless stated; derate for higher temperatures and other media per GF's pressure–temperature diagrams.